Siemens西门子 5SW3312 交流断路器-产品快照
- 品牌:
- Siemens
- 型号:
- 5SW3312
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
众业达电气(深圳)有限公司 | 0755-89314987 | irene.li@zyd.cn,13509669211 |
大连鼎宏科技有限公司 | 0411-83693111 | |
东莞市欧能自动化设备有限公司 | 18680502757 | |
福建萤光电气科技发展有限公司 | 18359060969 | |
福州福大自动化科技有限公司 | 0591-28482265 | |
广州锋力五金机电有限公司 | 020-87359185 | |
广州汇尼克机电设备有限公司 | 020-85549829 | |
广州市黄埔区科技开发总公司 | ||
海格曼商贸(上海)有限公司 | 4008215282 | |
深圳市格雷创科技有限公司 | 400-811-6961 | 微信及邮件咨询,官网:www.gchane.com |
深圳市行健自动化股份有限公司 | 0755-86336499 | |
深圳市昊普锐科技有限公司 | 0755-82127363 | |
深圳市朗助机电有限公司 | 0755-83975718 | |
深圳市曼伯特实业发展有限公司 | 0755-82032366 | |
苏州工品汇信息科技有限公司 | 4000496999 |
产品介绍
Siemens西门子 5SW3312 交流断路器
Locking Device, Padlock For Use With 5SM3 Series
Siemens
Series 5SM3 RCCBs Residual Current operated circuit breaker for Personnel and fire protectionFree from FCKW and silicone2 or 4 poleInstant tripping, surge current withstand capability >1kAMains connection alternatively from above or underneathReciprocally sleeve terminals with wire protection Lower combination clamp for the simultaneous connection of bus bars and leadersSafe and rapid connection of the feeder cables due to relocation of busbar at the rearN-Connection on the left allows easy busbar mounting with pin busbar if the miniature circuit breakers are fitted on the right.DIN rail mounting (TH 35 according to DIN EN 60715)Equipment life span: >10 000 Switching cyclesAn auxiliary circuit switch can be fitted to the right hand side of the enclosure by the customerOperating handle and test button can be locked by means of a hand locking deviceEnclosure: IP20Dimensions (HxD): 90x70mmDimensions (width): 2 pole 36mm; 4 Pole 72mmAmbient temperature: -5→+45 °C Standards IEC/EN 61008 Siemens RCDs, RCBOs, RCCBs and MCBs Type B characteristic offers instantaneous short circuit response level of 3-5 x normal rated current, making it suitable for circuits with moderate inrush currents such as filament lamps, heating loads and most domestic/small building protection applications.,Type C characteristic offers short circuit response of 5-10 x normal rated current, making it ideal for circuits with higher inrush currents such as motor control and fluorescent lighting installations in industrial buildings where nuisance tripping might occur if a faster type was used. Type D characteristic is designed for high inrush loads. Magnetic trip point - 10 to 20 times In rating. Thermal trip point - 1.13to 1.45 protector rating. Type AC characteristic ensure tripping for sinusoidal, alternating currents, whether they be quickly applied or slowly to increase. ; Accessory Type Locking Device, Padlock; For Use With 5SM3 Series;
Automation & Control Gear>Circuit Protection & Circuit Breakers>Padlocking & Locking Accessories