供应商名称 | 电话 | 备注 |
---|---|---|
福禄克公司 | ||
深圳华南城信息技术有限公司 | 400-1848-666 | 工业品MRO商城 |
深圳市连讯达电子技术开发有限公司 | 0755-83999818 | 专注福禄克FLUKE |
青岛东方嘉仪电子科技有限公司 | 0532-83812497 | |
TME | ||
深圳市三浦贸易有限公司 | 4008 824 824 | |
北京泰亚赛福科技发展有限责任公司 | 010-84851836 | |
固安捷(中国)工业品销售有限责任公司 | 800-820-5151 | |
欧时电子元件(上海)有限公司 | ||
深圳维多利斯科技有限公司 | 0755-83618590 | |
北京天创精电科技有限公司 | 400-040-1718 | 进口仪器仪仪表 |
产品介绍
Fluke福禄克 1551A-9 测温仪
Fluke 1551 Digital Thermometer, 1 Input Handheld, RTD Type Input, Intrinsically Safe
Fluke
Fluke 1551A Ex/1552A Ex Intrinsically Safe "Stik" Thermometer The Fluke ATEX thermometer is an intrinsically safe, battery operated thermometer, with a range from -50°C to +160°C. Housed in a rugged stainless steel sheath, you no longer have to worry about breaking a mercury-in-glass thermometer. The probe and digital readout are fixed together, calibrated as a system and accurate to +/- 0.05°C over the full temperature range. The large LCD display features a bright backlight, and rotates 90°, making it easy to read from any position. Measurement errors are minimised with a user configurable temperature trend / stability indicator, which tells you when your temperature source is stable or if your temperature is trending up or down. Whether working outdoors, or in potentially hazardous environments, this portable reference thermometer is designed to go where you work 12in. Probe Sheath +/- 0.05°C accuracy over full range ATEX compliant Display temperature in °C or °F Datalogging to internal memory Temperature trend indicator User selectable resolution (0.1, 0.01, 0.001) 300 hour battery life Percent battery life & low battery indicator NVLAP accredited calibration certificate (NIST Traceable)Operating Temperature Range of Readout: -10°C to +50°C Storage Temperature: -20°C to +60°C, 0 to 95% RH, non-condensing Data Logging: Up to 10k time-stamped readings stored to internal memory Logging Intervals: 2, 5, 10, 30 or 60 seconds; 2, 5, 10, 30 or 60 minutes Averaging: Moving average of most recent 2 to 10 readings, user selectable (ON / OFF, 2, 5, 10) Communications: RS-232 stereo jack (access calibration parameters only) EMC Compliance: EN61326:2006 Annex C; CISPR II, Edition 5.0-2009; Class "B" Enclosure Rating: IP50 Calibration: NVLAP Accredited Calibration Certificate (NIST Traceable) Characterisation: CVD Dimensions: 114 x 57 x 25mm Weight: 196g Warranty: 1 year 1551A Ex 1552A Ex Temperature range -50 °C to 160 °C(-58 °F to 320 °F) -80 °C to 300 °C( -112 °F to 572 °F) Accuracy (1 year) ± 0.05 °C (± 0.09 °F) ± 0.05 °C (± 0.09 °F) Sensor type 100 Ω thin-film RTD 100 Ω wire-wound PRT Probe temperature coefficient 0.00385 Ω/Ω/°C nominal 0.00385 Ω/Ω/°C nominal Sensor length ≤ 10 mm ≤ 30 mm Minimum immersion depth 7 cm (2.8 in) 12 cm (4.8 in) Probe sheath material SST SST Response time 4.8 mm diameter probe (3/16 in): 14 seconds6.35 mm diameter probe (1/4 in): 21 seconds 4.8 mm diameter probe (3/16 in): 14 seconds6.35 mm diameter probe (1/4 in): 21 seconds Characterization CVD ITS-90 Note Model number appended with a -9, -12, -20 indicates probe sheath length in inches. All probe diameters are 6.35 mm with the exception of the 1551A-9, which is 4.8 mm diameter Supplied with 3 x AAA batteries and instruction manual on CD ROM Industrial Thermocouple ; Absolute Maximum Temperature Measurement +160°C; Thermometer Type Handheld; Probe Type RTD; Application Industrial; Best Accuracy ±0.05 °C; Number of Temperature Inputs 1; Resolution 0.001 °C; Length 114mm; Width 57mm; Height 25mm; Dimensions 114 x 57 x 25mm; Minimum/Maximum Recordings Yes; Hazardous Area Certification ATEX; Model Number p 1551; Battery Type AAA; Intrinsically Safe Yes; Weight 196g; Temperature Scale Centigrade, Fahrenheit;
Digital Thermometers