Mirion  MG-RAF-1233245 测量仪表

Mirion MG-RAF-1233245 测量仪表-产品快照

品牌:
Mirion
型号:
MG-RAF-1233245

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
暂无展示,可咨询在线客服 400-811-6961 微信咨询,as10@gchane.com , QQ3350168184

Mirion供应商或现货商入驻,请点击>>

产品介绍

Mirion MG-RAF-1233245 测量仪表

RDS-80 Contamination Survey Meter

Mirion Technologies (MGP)

The RDS-80 Surface Contamination Meter is a versatile contamination detector which has been designed for a wide range of applications in different i elds of radiation protection in nuclear industry, rescue and other operations, involving a possibility for abnormal contamination levels. RDS-80 Surface Contamination Meter The RDS-80 Surface Contamination Meter  is a versatile contamination detector which has been designed for a wide range of applications in different i elds of radiation protection in nuclear industry, rescue and other operations, involving a possibility for abnormal contamination levels. The Digital, Hand Held Pulse Rate Meter is suitable for personnel who need to locate and detect contaminated surfaces/objects during their work. The functions comprise contamination measurements with alarm functions and automatic conversion to activity value and additionally surface contamination measurement with a possibility to store the histogram events into the meter´s internal memory.  The use of coni guration software (CSW) is required for downloading the data into a PC via IrDA port). Features: Wide measurement range: up to 100 000 cps or 100 000 Bq/cm2 Standard surface contamination measurements in cps or Bq/cm2 Contamination measurements with histogram function Visual and audible alarms Handy and easy to use design Software for parameter setting, histogram readings and nuclide calibration TECHNICAL SPECIFICATIONS: Radiological Characteristics Radiation detected: alpha >2 MeV, beta >100 keV, gamma and x-rays from 5 keV to 1.3 MeV Detector:  end window GM tube, 1,5-2 cm2; MICA window Ø 4.4 cm (1.74”) Measurement range: surface contamination 1 to 100 000 cps or 0.01 to 100 000 Bq/cm2 Alarm levels:  freely adjustable alarm levels for contamination level Cps linearity: ±15% ±1 digit over the range. The Bq/cm2 display is calculated from cps values by multiplying with Isotope coefi cient Functional Characteristics Display in either cps or Bq/cm2 Surface activity (Bq/cm2) display coni gurable for different nuclides Cps follow-up by audible signal with frequency proportional to activity Visual and audible alarm: user settable for surface activity Histogram capability of up to 480 points with user settable logging interval Backlit display with six large digits Built-in self diagnostics Gamma background reduction for Bq/cm2 measurements Built-in infra-red port (IrDA) Electrical Characteristics Power supply: 2 alkaline batteries IEC LR6/AA size (recommended) Battery life time: at least 2000 hours at normal background with alkaline cells (more than 1 year under normal operation) Battery alarm: two-step alarm for low battery voltage Electromagnetic compatibility: CE compliant Mechanical Characteristics Rugged plastic case Dimensions: 78 x 126 x 57 mm Weight:280 g  without batteries, 330 g with batteries Environmental Characteristics Temperature range: -25...+55°C operational (-13... 131°F) -40...+70°C storage (-40... 158°F) protection level IP67 (temporary immersion / l oating device) Accessories CSW software for parameter setting and histogram readings (can be downloaded free of charge at www.mirion.com) CSW-Confi guration SW full version with calibration key ( item no. 1233-246) Wrist strap Neck strap Login or Register to write the first review.

Description RDS-80 Surface Contamination Meter The RDS-80 Surface Contamination Meter  is a versatile contamination detector which has been designed for a wide range of applications in different i elds of radiation protection in nuclear industry, rescue and other operations, involving a possibility for abnormal contamination levels. The Digital, Hand Held Pulse Rate Meter is suitable for personnel who need to locate and detect contaminated surfaces/objects during their work. The functions comprise contamination measurements with alarm functions and automatic conversion to activity value and additionally surface contamination measurement with a possibility to store the histogram events into the meter´s internal memory.  The use of coni guration software (CSW) is required for downloading the data into a PC via IrDA port). Features: Wide measurement range: up to 100 000 cps or 100 000 Bq/cm2 Standard surface contamination measurements in cps or Bq/cm2 Contamination measurements with histogram function Visual and audible alarms Handy and easy to use design Software for parameter setting, histogram readings and nuclide calibration TECHNICAL SPECIFICATIONS: Radiological Characteristics Radiation detected: alpha >2 MeV, beta >100 keV, gamma and x-rays from 5 keV to 1.3 MeV Detector:  end window GM tube, 1,5-2 cm2; MICA window Ø 4.4 cm (1.74”) Measurement range: surface contamination 1 to 100 000 cps or 0.01 to 100 000 Bq/cm2 Alarm levels:  freely adjustable alarm levels for contamination level Cps linearity: ±15% ±1 digit over the range. The Bq/cm2 display is calculated from cps values by multiplying with Isotope coefi cient Functional Characteristics Display in either cps or Bq/cm2 Surface activity (Bq/cm2) display coni gurable for different nuclides Cps follow-up by audible signal with frequency proportional to activity Visual and audible alarm: user settable for surface activity Histogram capability of up to 480 points with user settable logging interval Backlit display with six large digits Built-in self diagnostics Gamma background reduction for Bq/cm2 measurements Built-in infra-red port (IrDA) Electrical Characteristics Power supply: 2 alkaline batteries IEC LR6/AA size (recommended) Battery life time: at least 2000 hours at normal background with alkaline cells (more than 1 year under normal operation) Battery alarm: two-step alarm for low battery voltage Electromagnetic compatibility: CE compliant Mechanical Characteristics Rugged plastic case Dimensions: 78 x 126 x 57 mm Weight:280 g  without batteries, 330 g with batteries Environmental Characteristics Temperature range: -25...+55°C operational (-13... 131°F) -40...+70°C storage (-40... 158°F) protection level IP67 (temporary immersion / l oating device) Accessories CSW software for parameter setting and histogram readings (can be downloaded free of charge at www.mirion.com) CSW-Confi guration SW full version with calibration key ( item no. 1233-246) Wrist strap Neck strap

Survey Meters

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。