
Mirion MG-RTM-A007 区域监视器-产品快照
- 品牌:
- Mirion
- 型号:
- MG-RTM-A007
* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.
供应商名称 | 电话 | 备注 |
---|---|---|
暂无展示,可咨询在线客服 | 400-811-6961 |
![]() |
产品介绍
Mirion MG-RTM-A007 区域监视器
AMP - 50
Mirion Technologies (MGP)
Click to enlarge The AMP-100 provides real-time remote radiological monitoring. Local readout of hand-held meter allows for use as a portable survey instrument. A M P - 5 0 GM Tube-Based Ratemeter and Area Monitor The AMP-50 provides real-time remote radiological monitoring. Local readout of hand-held meter allows for use as a portable survey instrument. More importantly, since the probe’s sensitive electronics are located far from the high field (25 to 350 feet away), they are not subject to destructive gamma exposure. The probe head may be placed directly into a filter compartment or against a resin tank or waste liner. TECHNICAL SPECIFICATIONS: Radiological Characteristics Detector: energy compensated GM-tube Detection range (± 10%): 10 μR/h to 4 R/h Energy range sensitivity: 17 cps per mR/hr Electrical Characteristics Power supply: 9 Volts (supplied by a 9 Volt battery located in the meter case) Optional 9 Volt AC adapter available Battery life: approximately 50 hours of continuous use Mechanical Characteristics Meter dimensions (w x h x d): 6.8 x 11.9 x 1.2 cm (2.7 x 4.7 x 0.5 in) Probe head length: 16.5 cm (6.5 in) Diameter: 3.3 cm (1.3 in) Standard cable length: 7.6 m (25 ft) Maximum cable length: 106 m (350 ft) Environmental Characteristics Temperature: -10° to 50°C (15 to 120° F ) Relative humidity: 10 to 95% RH (non-condensing) FEATURES The AMP-50 is designed specifically to be used in medium to low dose rate fields. The AMP-50 features linear response from 10 μR/h to 4 R/h (0.1 μsv/hr to 40 msv/hr) Rugged construction, waterproof detector housing and cable Quick-disconnect connectors allow customization of cable length and facilitate easy decontamination Built-in communication port for use with DDC-16, WRM transmitter... «smoothed» digital display offers accurate, stable readings User-selectable internal alarm threshold Login or Register to write the first review.
Description A M P - 5 0 GM Tube-Based Ratemeter and Area Monitor The AMP-50 provides real-time remote radiological monitoring. Local readout of hand-held meter allows for use as a portable survey instrument. More importantly, since the probe’s sensitive electronics are located far from the high field (25 to 350 feet away), they are not subject to destructive gamma exposure. The probe head may be placed directly into a filter compartment or against a resin tank or waste liner. TECHNICAL SPECIFICATIONS: Radiological Characteristics Detector: energy compensated GM-tube Detection range (± 10%): 10 μR/h to 4 R/h Energy range sensitivity: 17 cps per mR/hr Electrical Characteristics Power supply: 9 Volts (supplied by a 9 Volt battery located in the meter case) Optional 9 Volt AC adapter available Battery life: approximately 50 hours of continuous use Mechanical Characteristics Meter dimensions (w x h x d): 6.8 x 11.9 x 1.2 cm (2.7 x 4.7 x 0.5 in) Probe head length: 16.5 cm (6.5 in) Diameter: 3.3 cm (1.3 in) Standard cable length: 7.6 m (25 ft) Maximum cable length: 106 m (350 ft) Environmental Characteristics Temperature: -10° to 50°C (15 to 120° F ) Relative humidity: 10 to 95% RH (non-condensing) FEATURES The AMP-50 is designed specifically to be used in medium to low dose rate fields. The AMP-50 features linear response from 10 μR/h to 4 R/h (0.1 μsv/hr to 40 msv/hr) Rugged construction, waterproof detector housing and cable Quick-disconnect connectors allow customization of cable length and facilitate easy decontamination Built-in communication port for use with DDC-16, WRM transmitter... «smoothed» digital display offers accurate, stable readings User-selectable internal alarm threshold
Area Monitors