供应商名称 | 电话 | 备注 |
---|---|---|
暂无展示,可咨询在线客服 | 400-811-6961 | 微信咨询,as10@gchane.com , QQ3350168184 |
产品介绍
Instek固纬 LCR-8105G
Instek LCR-8105G, 20 Hz to 5 MHz Precision LCR Meter
Instek
Single-layer menu makes set up and operation quick and easy Wide test frequency 20 Hz to 1, 5, and 10 MHz Measures 11 different parameters with 0.1% basic accuracy 6-digit measurement resolution Large LCD display with intuitive user interface Full measuring functions with DUT V/I monitor Pass/fail function with judgment alarm DC resistance measurement Multi-step mode Graph mode for visual characterization RS-232C and GPIB interface standard These LCR meters provide accuracy, versatility, and high resolution, for a wide range of component measurements, including DC resistance measurement and voltage/current monitoring. Use the multi-step function for on-screen programming of customized measurement sequences with pass/fail indication. Each program includes 30 test steps and each test step can be set with selected parameters and test limits. These meters automate tedious manual work routines with the press of a button. In graph mode, select the parameter, set the start/stop voltage or the start/stop frequency of the sweep, and meters run through the sequence of measurements displaying the component characteristics in graphical format. The standard GPIB and RS-232C interfaces provide easy instrument control and downloadable results to your PC. An LCR meter and other electrical testing equipment are vital to industrial projects. Large capacitors common in industrial power systems can fail without appearing faulty at all. This is why a capacitor meter, tester, or checker is a must-have piece of gear. An LCR meter typically isn’t that difficult to use. But using an LCR, like most electrical testers, takes a bit of finesse. An LCR meter has the ability to measure test frequencies, and other parameters such as adjustable equivalent circuit measurement. But sometimes measurements may mysteriously come up inaccurate on an LCR meter. Selecting the wrong settings, measuring the wrong frequencies and other common problems may lead to inaccurate readings. To help avoid such mistakes try the following: review the LCR meter manual for accuracy recommendations, calculate impedance at the application frequency and ensure capacitors are discharged before you start a measurement. If you have questions about an LCR meter and its use contact a Davis Application Specialist today. What's Included: Test lead with kelvin clip (4 wire type) and power cord. Specifications Test Frequency 20 Hz to 1 MHz, 20 Hz to 5 MHz, 20 Hz to 10 MHz Product Type LCR Meter Frequency Accuracy ±0.1% Input impedance 100 ohm Test speed AC (>2kHz) Max: 75 mS; Fast: 150 mS; Medium: 450 mS; Slow: 600 mS Test Speed DC Max: 30 mS; Fast: 60 mS; Medium: 120 mS; Slow: 900 mS Short circuit current 20 mA (max) Interface RS-232C, GPIB Parameters Measured Impedance (Z), Phase Angle ( ), Inductance (L), Capacitance ©, AC Resistance (Rac), Quality Factor (Q), Dissipation Factor (D), Admittance (Y), Conductance (G), Reactance (X), Susceptance (B), DC Resistance (Rdc) Qty/ea 1 Manufacturer number LCR-8105G Brand Instek Power 115 VAC (+10% / -25%), 230 VAC (+15% / -14%) (Selectable), 50/60Hz Display 320 x 240 Dot matrix LCD Dimensions 13" W x 6.6" D x 13.3 H (330 x 170 x 340 mm)
Electronic Test Equipment Component Testers - LCR/ESR/Analyzers Instek Precision LCR Meter