EATON伊顿  PFR-003 差动继电器

EATON伊顿 PFR-003 差动继电器-产品快照

品牌:
EATON
型号:
PFR-003

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
深圳市格雷创科技有限公司 400-811-6961 微信及邮件咨询,官网:www.gchane.com
上海亦翔电气技术有限公司 021-61488548
深圳市欧捷诚科技有限公司 0755-26650315
苏州哈德控制技术有限公司
上海沪朗电气有限公司 15905696881
杭州捍特电气有限公司 021-51720278
伊顿(中国)投资有限公司 021-52000099

EATON供应商或现货商入驻,请点击>>

产品介绍

EATON伊顿 PFR-003 差动继电器

PFR-003 285555 EATON MOELLER electronic differential relay, 30mA

EATON - MOELLER

electronic differential relay, 30mA

Delivery programme Rated fault currents I Δn A 0.03 Description Pulse-current sensitive Integrated auxiliary contact (1 C/O) Ring-type transformer must also be ordered not UL/CSA approved Rated control voltage U s V 230 V AC 50/60Hz Technical data Electrical Standards IEC/EN 60947-2, IEC 755, IEC 1008, IEC 1009 Sensitivity Pulse current sensitive, type A Rated control voltage U s V AC 230 ±20 % (50/60 Hz) Motor rating P e W 3 Rated fault currents I Δn A 0.03 Delay time t v s 0.02 (non-delayed) Relay contacts 1 integrated changeover contact Rated voltage of the relay contact V AC/DC 250/100 Rated current of the relay contact A 6 Mechanical Standard front dimension mm 45 Enclosure height mm 85 Device width mm 45 Mounting Snap fixing, top-hat rail DIN 46277, IEC/EN 60715 Terminals top and bottom Box terminals Terminal protection Finger/back-of-hand proof to BGV A2, VDE 106 part 100 Terminal capacities mm 2 2 x 0.75 - 2.5 solid, 2 x 0.75 - 1.5 flexible/with ferrules Ambient temperature Operation °C -10 - +50 Design verification as per IEC/EN 61439 (Show features) (Hide features) Technical data for design verification Operating ambient temperature min. °C -10 Operating ambient temperature max. °C 50 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 Low-voltage industrial components (EG000017) / Residual current release for power circuit breaker (EC001021) Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Fault current switch for circuit breakers ( [email protected] [AKF009010]) Rated control supply voltage Us at AC 50HZ V 184 - 276 Rated control supply voltage Us at AC 60HZ V 184 - 276 Rated control supply voltage Us at DC V 0 - 0 Rated fault current A 0.03 - 0.03 Max. power on-delay time ms 20 Delay adjustable No Max. rated operation voltage Ue V 276 Dimensions IL01219036Z (AWA1230-2214) Residual-current relay: converter for earth-leakage circuit-breaker >>

Categories:

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。