Megger   CR-19092 高压继电器

Megger CR-19092 高压继电器-产品快照

品牌:
Megger
型号:
CR-19092

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
暂无展示,可咨询在线客服 400-811-6961 微信咨询,cs11@gchane.com , QQ1429311537

Megger供应商或现货商入驻,请点击>>

产品介绍

Megger CR-19092 高压继电器

Megger SVERKER900 3-Phase Relay & Substation Test System - Standard

Megger

Upgraded version of the SVERKER900 Basic Kit Powerful, multifunctional relay test system Built-in touchscreen Megger SVERKER900 3-Phase Relay & Substation Test System - Standard Details Note: there are three versions of the Megger SVERKER900 Test Set available: Basic, Standard and Expert. This is the Standard kit, which includes the following (new features compared to the Basic Kit are outlined in bold): Main Instrument - with timing tests, manual determination of pick-up and drop-out of relay contact and set, inject and measure functions Prefault-Fault Instrument  - perform timing tests which require simulation of a prefault state before fault simulation CT Magnetisiation Instrument - determine the knee point of voltage of the current transformer Ramping Instrument - automatically determine pickup threshold and perform time testing Sequencer Instrument - simulate sequences such as auto recloser, motor start or re-striking earth faults Megger's SVERKER900 is a powerful, multifunctional relay and substation test system designed to give professional technicians all the tools they need to perform secondary and primary testing of relay protection within electrical distribution substations, renewable power generation stations and industrial applications. With the SVEKER900, you'll have everything you need for three-phase secondary testing of protection devices, plus primary testing. You can use this unit for a wide variety of tasks including commissioning and maintenance of distributed/generator power in substations, testing electromechanical, static and numerical protection relays and much, much more. Portable with a built-in carrying handle for easy transportation, the SVERKER900 can be configured to your specific application using a fast response, full colour built-in LCD touchscreen. A wide variety of inputs and outputs cater for practically any testing appliation. The Megger SVERKER900 Relay Test System is suitable for use with a huge range of relays, including: distance protection/under impedance, overfluxing, synconising/synchornism-check, undervoltage, directional power, undercurrent/underpower, loss of field, negative sequence overcurrent, phase sequence voltage, thermal, overcurrent/ground fault, power factor, overvoltage, DC overcurrent and a wide variety of other relays. Megger SVERKER900 Interface Breakdown The following table outlines exactly what's included on the SVERKER900's front interface. 1 - Binary Inputs (1-4) The binary inputs are independtly programmable gate circuits that permit simple selection of the desired mode for voltage or contact monitoring operations. Binary input 1 has a selectable threshold voltage 2 - Extra Timer With separate start/stop inputs, the timer can be used to measure both external cycles and sequences initiated by the SVERKER900. The measured time appears on the display. Each input can be set to respond to the presence of abscence of voltage (AC/DC) at a contact 3 - Binary Output The binary output is used to simulate normally open/normally closed contacts for testing breaker failure schemes, or similar power system operations. In addition it may also be used to switch AC/DC voltages and currents 4 - Current/Voltage Current and voltage are measured by the built-in ammeter and voltmeter. Resistance, impedance, phase angle, pwer and power factor can also be measured. Readings appear on the display. These instruments can also be used to take measurements in external circuits 5 - Current Generators The current generators can be used separately, in parallel or series. The current generators deliver maximum compliance voltage to the load constantly during the test, and range changing is done automatically, on-the-fly, under load. 6 - Voltage Generators The voltage generators can be used separately, in parallel or series 7 - USB For external keyboard, mouse, saving test data and for updating internal SW 8 - Mains Inlet 9 - Ground (Earth) Connection 10 - On/Off Switch 11 - Ethernet Port For authorised service actions 12 - Touch Screen 5.7" full colour LCD 13 - Control Knob For setting of current, voltage and other parameter values Megger SVERKER900 Three-Phase Relay/Substation Test System Key Features Full toolbox for substation 3-phase testing Three current and four voltage sources Standalone functionality Rugged and reliable with integrated carrying handle for use in the field Generation 900V and 105A in single-phase mode Secondary and primary testing Fast response LCD colour touchscreen What's Included? SVERKER900 Test Unit Ten Jumpers Touch Screen Pen Test Cable Set Protective Cable Cable Set (up to 900V) Flight Case with Wheels

1 - Binary Inputs (1-4) The binary inputs are independtly programmable gate circuits that permit simple selection of the desired mode for voltage or contact monitoring operations. Binary input 1 has a selectable threshold voltage 2 - Extra Timer With separate start/stop inputs, the timer can be used to measure both external cycles and sequences initiated by the SVERKER900. The measured time appears on the display. Each input can be set to respond to the presence of abscence of voltage (AC/DC) at a contact 3 - Binary Output The binary output is used to simulate normally open/normally closed contacts for testing breaker failure schemes, or similar power system operations. In addition it may also be used to switch AC/DC voltages and currents 4 - Current/Voltage Current and voltage are measured by the built-in ammeter and voltmeter. Resistance, impedance, phase angle, pwer and power factor can also be measured. Readings appear on the display. These instruments can also be used to take measurements in external circuits 5 - Current Generators The current generators can be used separately, in parallel or series. The current generators deliver maximum compliance voltage to the load constantly during the test, and range changing is done automatically, on-the-fly, under load. 6 - Voltage Generators The voltage generators can be used separately, in parallel or series 7 - USB For external keyboard, mouse, saving test data and for updating internal SW 8 - Mains Inlet 9 - Ground (Earth) Connection 10 - On/Off Switch 11 - Ethernet Port For authorised service actions 12 - Touch Screen 5.7" full colour LCD 13 - Control Knob For setting of current, voltage and other parameter values Specifications are valid for resistive load, at 170-240 voltage supply and ambient temperature +25°C ±3°C (77°F ±5.4°F) after 30 minutes warmup time and in the frequency range of 10Hz to 70Hz. All hardware data are for full scale values. Specifications are subject to change without notice. Environment Application Field For use in high-voltage substations and industrial environments Operating Temperature 0 to 50°C (32 to +122°F) Storage/Transport Temperature -40 to +70°C (-40 to +158°F) Humidiity 5 to 95% RH, non-condensing Altitude (Operational) 2000m (6500ft) Shock and Vibration IEC 60068-2-27 Vibration IEC 60068-2-6 CE-Marking EMC IEC61326-1 LVD IEC61010-1: 2010 General Mains Input 100 to 240V AC, 50/60Hz Current Consumption 10A (max) Power Consumption 1800VA (max) Instrument Dimensions 350 x 270 x 220mm (13.8 x 10.6 x 8.7") Flight Case with Wheels 615 x 295 x 500mm (24.2 x 11.6 x 19.7") Flight Case 620 x 295 x 500mm (24.4 x 11.6 x 14.4") Weight 14.9kg (32.8lbs) - instrument only 29.0kg (64lbs) with accessories and flight case (with wheels, GD-00185) 23.9kg (52.7lbs) with accessories and flight case (GD-00182) Display 5.7" LCD touch screen Available Lanugages English, French, German, Spanish and Swedish Measurement Section Binary Inputs 1,2, 3, 4 and EXTERNAL TIMER Start/Stop Number 6 Type Dry or wet contacts max, 240V AC or 340V DC Galvanic Isolation 35 minutes Max Measuring Time Settable, 0 to 999ms BINARY INPUT 1 Settable, 0 to 999ms Timer Range Inaccuracy 0 to 50ms ≤1ms 50 to 500ms ≤2ms >500ms ≤1% Resolution 1ms Voltmeter Measurement Method AC true RMS DC mean value Insulation 900V, 1273 peak Input Rating 900V Inaccuracy (DC Ranges) 0 to 1V ±0.5% of reading + 3mV 0 to 10V ±0.5% of reading + 7mV 0 to 100V ±0.5% of reading + 30mV 0 to 900V ±0.5% of reading + 300mV Inaccuracy (AC Ranges) 0 to 1V ±1% of reading + 5mV 0 to 10V ±1% of reading + 10mV 0 to 100V ±1% of reading + 50mV 0 to 900V ±1% of reading + 300mV Resolution 1mV Frequency Range 10Hz to 600Hz Inaccuracy <0.01% Resolution >10mHz Ammeter Measurement Method AC true RMS DC mean value Inaccuracy (DC Ranges) 0 to 200mA ±0.5% of reading + 2mA 0 to 1.5A ±0.5% of reading + 3mA 0 to 10A ±0.5% of reading + 10mA Inaccuracy (AC Ranges) 0 to 200mA ±1% of reading + 2mA 0 to 1.5A ±1% of reading + 3mA 0 to 10A ±1% of reading + 20mA Frequency Range 10Hz to 600Hz Inaccuracy <0.01% Resolution <10mHz Extra Measurements Power Factor Range 0.01 (cap) to 1 to +0.01 (ind) Resolution <0.01 Inaccuracy <0.04 Phase Angle (°) Range 0 to 360 ° Resolution <0.1 ° Inaccuracy <0.8 ° Impedance and Power Measurement AC Z(Ω), R(Ω),X (Ω), P(W), S(VA), Q(VAR) DC R(Ω), P(W) Range Up to 999kX (X = unit) Binary Outputs Insulation 250V AC Current 1A (max) Voltage 250V AC Generation Section Voltage outputs U1, U2, U3 and U4/DC out All voltage sources/generators are galvanically separated from each other and from ground. Floating common return is made by using jumper connectors Ranges 4-Phase AC 4 x 300V 4-Channel DC 4 x 300V Power 4-Phase AC 4 x 125VA (max) 4-Channel DC 4 x 125W (max) Inaccuracy 0.03% range + 0.05% of reading) Distortion (THD + N) <0.14% typical (0.25% max) Resolution 10mV Phase Angle Range 0 to 360° Inaccuracy <0.5° (at 50-60Hz) Resolution 0.1° Frequency Range 10Hz to 600Hz Inaccuracy <0.03% (45 to 66Hz) Resolution 1mHz

Home High Voltage, Utility & Rail Current Injection & Relay Test Sets Relay Test Sets

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。