Megger   CD-12390 高压继电器

Megger CD-12390 高压继电器-产品快照

品牌:
Megger
型号:
CD-12390

* 所有产品信息均源于第三方公开数据或用户上传,工业链仅整合供参考,真实价格货期请联系供应商确认.


供应商名称 电话 备注
暂无展示,可咨询在线客服 400-811-6961 微信咨询,cs10@gchane.com , QQ1653501665

Megger供应商或现货商入驻,请点击>>

产品介绍

Megger CD-12390 高压继电器

Megger SVERKER750 Multifunction Single Phase Relay Test Set

Megger

Portable relay testing system with integrated carrying handle Huge range of testing functions Intuitive, easy-to-use system with built-in digital display Megger SVERKER750 Multifunction Single Phase Relay Test Set Details The Megger SVERKER750 is the engineer's toolbox for secondary testing of protective relay equipment. The SVERKER750 can be used to test a wide variety of equipment, including overcurrent relays, inverse time overcurrent relays, undercurrent relays, ground fault relays, directional overcurrent relays, undervoltage relays, power factor relays, time-delayed relays and much, much more. Whether you're new to the SVERKER family or have used other models such as the SVERKER650 in the past, the SVERKER750's intuitive interface with local layout and built-in digital screen make the system as simple to use as possible. Once configured, the SVERKER750 can be used to measure and display time, voltage, current, Z, R, X, S, P, Q, phase angle and cos φ. You can also use the Megger SVERKER750 for a wide variety of other applications including plotting excitation curves, current/voltage transformer ratio tests, burden measurements, impedance measurements, efficiency tests, polarity tests and more. For added convenience the SVERKER750 even comes with a useful carrying handle for easy porting from test to test. Megger SVERKER750 Feature/Benefit Breakdown The following table outlines the functionality of the Megger SVERKER750. 1 - Set of Resistors Made for fine adjustments and regulation of current and voltage 2 - Start and Stop Conditions The timer's start and stop inputs respond to changes, voltage or contact closing/openings. The timer's start input is also used when testing auto-reclosing relays to synchronise two or more SVERKER units and to start generation with an external signal 3 - Display Shows time, current, voltage and other parameters. Also used to make settings (access setting mode by pressing MODE button) 4 - Freeze Function (HOLD) Makes it possible to measure voltage and current as short as a quart of a mains voltage period by saving a reading on the display. Voltage and current readings are frozen when the timer stops. If it doesn't stop, the reading present when the current was interrupted is frozen on the display. 5 - Make/Break Contact Changes state automatically when a test is started. Can be used (for example) to synchronise two or more SVERKER units, other external equipment or to switch the voltage applied to the protective relay equipment back and forth between faulty and non-faulty. 6 - Ammeter and Voltmeter Current and voltage are measured by the built-in ammeter/voltmeter. Resistance, impedance, phase angle, power and power factor can also be measured. Reading appear on the display. These instruments can also be used to take measurements in external circuits. The voltmeter can also be used as 2nd ammeter (when testing differential relays, for example, using CSU20A). Current and voltage can be displayed either as amperes or volts or as percantages of a given voltage or current (the present settings of the protective relay equipment, for example). 7 - Current Source Provides 0-250A AC, 0-250V AC or 0-300V D, depending on the ouput being used. Setting are made using the main knob. The readings of current, voltage and other entities appear on the display. The start switch is used to turn the current source on and off. When time is being measured, this is done in synchronisation with the timer. 8 - Auxiliary Voltage Source Provides 20-220V DC in two ranges. Equipped with overload protection and separate from the other outputs. Used frequently to supply the object being tested. 9 - Status Indicator The timer's start and stop inputs are each equipped with indicator lamps which, when lighted, indicate a closed circuit (useful for detecting contact closings/opening) or the presence of voltage. These indicator lamps make it possible (for example) to check circuits before starting a measurement cycle. 10 - Timer Inputs The timer has separate start and stop inputs, and it can be used to measure both external cycles and sequences initiated by the SVERKER. The measured time appears on the display. Each input can be set to respond to the presence of absence of voltage (AC/DC) at a contact. 11 - Start Switch Controls the turning on and off of the current source and timer. Can be set to one of four states. ON+TIME. Starts generation and timing simultaneously. Used to test over current, voltage or other parameter relays. Generation continues a) until the protective relay equipment operates and stops the timer or b) until the maximum time expires or the start switch is released if time-limited generation has been selected. OFF function turns of the current source, wherupon generation is interrupted. ON function turns on the current source in the generating state. OFF+TIME function interrupts generation and starts the timer simultaneously. Used when testing current, voltage or other parameter relays. The timer is stopped when the protective relay equipment operates. When automatically reclosing is set to be tested, the SVERKER can be set to start a new generation when the timer's start input is activated by the closing command. 12 - Computer Interface (USB) Serial port for communication with PC and SVERKER Win PC software 13 - Tripping Indicator Lights when a stop condition is fulfilled to indicate operation of the protective relay equipment. If the test being conducted incorporates timing, this indicator starts to blink when relay operation occurs. 14 - Main Knob Used to set current output from the current source 15 - AC Voltage Source Since the AC voltage source is separated from other outputs, it is set independently of the current source. The AC voltage source is intended primarily for the relay protection equipment's voltage input Megger SVERKER750 Relay Test Set Key Features Portable solution for testing a wide variety of single phase relays Built-in carrying handle for easy transportation Rugged and reliable design for field use Logical design with simple interface Display can show time, voltage, current, Z, R, X, S, P, Q, phase angle and cos φ Intergated voltmeter and ammeter Variable voltage source Serial port for communication with PC and SVERKER Win PC software (software sold separately) Two SVERKER units can be synchronised to create a basic 3-phase test set Suitable for voltage relays with frequency range from 15Hz up to 550Hz Use to plot excitation curves Suitable for burden measurements on protective relays Impedance, efficiency and polarity measurement possible What's Included? Megger SVERKER750 Relay Test Set (230V) Test Lead Set (GA-00030) Transport Case Optional Accessories CD-8102X: SVERKER Win PC Software + RS232/USB Cables (please specify SVERKER serial number when ordering) CSU20A: 230V Current and Voltage Source PSS750: Phase Selector Switch AA-00100: Cable Organiser (Velcro Straps x 10)

1 - Set of Resistors Made for fine adjustments and regulation of current and voltage 2 - Start and Stop Conditions The timer's start and stop inputs respond to changes, voltage or contact closing/openings. The timer's start input is also used when testing auto-reclosing relays to synchronise two or more SVERKER units and to start generation with an external signal 3 - Display Shows time, current, voltage and other parameters. Also used to make settings (access setting mode by pressing MODE button) 4 - Freeze Function (HOLD) Makes it possible to measure voltage and current as short as a quart of a mains voltage period by saving a reading on the display. Voltage and current readings are frozen when the timer stops. If it doesn't stop, the reading present when the current was interrupted is frozen on the display. 5 - Make/Break Contact Changes state automatically when a test is started. Can be used (for example) to synchronise two or more SVERKER units, other external equipment or to switch the voltage applied to the protective relay equipment back and forth between faulty and non-faulty. 6 - Ammeter and Voltmeter Current and voltage are measured by the built-in ammeter/voltmeter. Resistance, impedance, phase angle, power and power factor can also be measured. Reading appear on the display. These instruments can also be used to take measurements in external circuits. The voltmeter can also be used as 2nd ammeter (when testing differential relays, for example, using CSU20A). Current and voltage can be displayed either as amperes or volts or as percantages of a given voltage or current (the present settings of the protective relay equipment, for example). 7 - Current Source Provides 0-250A AC, 0-250V AC or 0-300V D, depending on the ouput being used. Setting are made using the main knob. The readings of current, voltage and other entities appear on the display. The start switch is used to turn the current source on and off. When time is being measured, this is done in synchronisation with the timer. 8 - Auxiliary Voltage Source Provides 20-220V DC in two ranges. Equipped with overload protection and separate from the other outputs. Used frequently to supply the object being tested. 9 - Status Indicator The timer's start and stop inputs are each equipped with indicator lamps which, when lighted, indicate a closed circuit (useful for detecting contact closings/opening) or the presence of voltage. These indicator lamps make it possible (for example) to check circuits before starting a measurement cycle. 10 - Timer Inputs The timer has separate start and stop inputs, and it can be used to measure both external cycles and sequences initiated by the SVERKER. The measured time appears on the display. Each input can be set to respond to the presence of absence of voltage (AC/DC) at a contact. 11 - Start Switch Controls the turning on and off of the current source and timer. Can be set to one of four states. ON+TIME. Starts generation and timing simultaneously. Used to test over current, voltage or other parameter relays. Generation continues a) until the protective relay equipment operates and stops the timer or b) until the maximum time expires or the start switch is released if time-limited generation has been selected. OFF function turns of the current source, wherupon generation is interrupted. ON function turns on the current source in the generating state. OFF+TIME function interrupts generation and starts the timer simultaneously. Used when testing current, voltage or other parameter relays. The timer is stopped when the protective relay equipment operates. When automatically reclosing is set to be tested, the SVERKER can be set to start a new generation when the timer's start input is activated by the closing command. 12 - Computer Interface (USB) Serial port for communication with PC and SVERKER Win PC software 13 - Tripping Indicator Lights when a stop condition is fulfilled to indicate operation of the protective relay equipment. If the test being conducted incorporates timing, this indicator starts to blink when relay operation occurs. 14 - Main Knob Used to set current output from the current source 15 - AC Voltage Source Since the AC voltage source is separated from other outputs, it is set independently of the current source. The AC voltage source is intended primarily for the relay protection equipment's voltage input Current Outputs - AC Range No-Load voltage (min) Full-Load Voltage (min) Full-Load Current (max) Load/Unload Times On (max) / Off (min) 0-10A 90V 75V 10A 2/ 15 minutes 0-40A 25V 20V 40A 1/ 15 minutes 0-100A 10V 8V 100A 1/ 15 minutes 0-100A 10V - 250A* 200A** 1 sec/ 5 minutes * Mains voltage 230V AC ** Mains voltage 115V AC Voltage Outputs - AC/DC Range No-Load Voltage (min) Full-Load Voltage (min) Full-Load Current (max) Load/Unload Times On (max) / Off (min) 0-250V AC 290V AC 250V AC 3A 10 min/ 45 min 0-300V DC 320V DC 250V DC 2A 10 min / 45 min Seperate AC Voltage Source (SVERKER 750) Range No-Load Voltage (min) Full-Load Voltage (min) Full-Load Current (Max) 0-60V AC 70V 60V 0.25A 60 to 120V AC 130V 120V 0.25A Both ranges are divided into voltage steps of 10V that are steplessly variable Separate AC Voltage Source (SVERKER 780) Range No-Load Voltage (min) Full-Load Voltage (min) Full-Load Power (max) 5-220V AC, minimim step 0.1V 240V AC 220V AC at 33W 200V AC at 46W 33W continuously. 46W 1 minute Phase Angle 0 to 359° Resolution 1° Inaccuracy ±2° Frequency 15 to 550Hz Resolution 1mHz Inaccuracy ±0.1% Auxiliary DC Output Range Voltage Max Current 20 to 130V 20V 130V DC 300mA 375mA 130 to 220V DC 130V 220V DC 325mA 400mA Environment Application Field This instrument is intended for use in HV substations and industrial environments Operating Temperature 0 to +50°C (32 to +122°F) Storage/Transport Temperature -40 to +70°C (-40 to +158°F) Humidity 5 to 95% RH non-condensing CE-Marking LVD Low voltage directive 2006/95/EC EMC EMC directive 2004/108/EC General Specifications Mains Voltage 115/230V AC, 50/60Hz Power Consumption (Max) 1380W Protection Thermal Cutouts, automatic overload protection Dimensions Instrument 250 x 270 x 220mm (13.8 x 10.6 x 8.7") Transport Case 610 x 350 x 275mm (24.0 x 13.8 x 10.8") Weight SVERKER 750 17.6kg (38.1lbs) 26.3kg (58lbs) with accessories + case SVERKER 780 18.1kg (39.9lbs) 27.1kg (59.7lbs) with accessories + case Other Specs Display LCD Languages Bulgarian, Czech, English, French, German, Russian, Spanish, Swedish and Turkish Ammeter Measurement Method AC, true RMS DC, mean value Ranges Internal 0.00 to 250.0A External 0.000 to 6.000A Inaccuracy (Internal Range) 0-10A AC ±(1% + 20mA) 0-40A AC ±(1% + 40mA) 0-100A AC ±(1% + 200mA) Inaccuracy (External Range) 0-0.6A AC ±(1% + 20mA) 0-6A AC ±(1% + 20mA) 0-0.6A DC ±(0.5% + 2mA) 0-6A DC ±(0.5% + 20mA) Resolution Internal Range 10mA (range <100A) 100mA (range >100A) External Range 1mA Voltmeter Measurement Method AC, true RMS Range 0.00 to 600.0V Inaccuracy AC, ±(1% + 200mV) Max value DC ±(0.5% + 200mV) Max value Values are range dependant Power Factor and Phase Angle Measurements Range Resolution Inaccuracy Power Factor cos φ -0.99 (cap) to +0.99 (ind) 0.01 ±0.04 Phase Angle cos φ (°) 000 - 359° 1° ±2° Impedance/Power Measurements AC Z (Ω and °), Z (Ω), R and X (Ω and Ω), P (W), S (VA), Q (VAR) DC R (Ω), P (W) Range Up to 999kΩ (X=unit) Make/Break Contact Max Current 1A Max Voltage 250V AC or 120V DC Reclosing Test Items Measured Tripping and reclosing times Display After test is finished a list of all times appears in the display Break State Feedback The make/break contact can be used to feed back the breaker state Max Number of Reclosings 49 Max Testing Time 999s

Home High Voltage, Utility & Rail Current Injection & Relay Test Sets Relay Test Sets

工业链是免费的公众性百科和搜索工具,收录展现海量信息,方便用户查找、认识和连接全球工业品,受众多用户支持、加入和上传,任何问题请联系工业链。

更多产品:

更多品牌:

对于国内有品牌官方销售机构的品类,建议直接咨询其国内机构;对于国内无官方销售机构、需从海外原厂采购的产品,或有相关问题,可联系工业链咨询了解;工业链非品牌官方原厂、代理商或办事处,仅按客户指定要求协助其从原厂或其授权代理采购原装产品,不代采任何品牌方不许可产品,网站制造品牌及其商标均归其权属人所有。