供应商名称 | 电话 | 备注 |
---|---|---|
暂无展示,可咨询在线客服 | 400-811-6961 | 微信咨询,cs10@gchane.com , QQ1653501665 |
产品介绍
AEMC PEL 102 能耗传感器
AEMC PEL 102 (2137.51) Power and Energy Logger, No Display; With Sensors
AEMC
Easy-to-use single, dual, and three-phase data loggers—only minimal programming required Provides all the necessary functions for power and energy data logging of 50, 60, 400 Hz and DC distribution systems Current measurements from 200 mA up to 10,000 A using flexible current sensors Automatic recognition of the connected current sensors/probes Power measurements: VA, W and var Energy measurements: VAh, Wh (source/load indication) and varh (including quadrant indication) Records cost of energy usage Features Power Factor, Cos, Tan, and DPF Total Harmonic Distortion (THD) for voltages and currents Harmonics up to the 50th order for 50/60 Hz voltages and currents and 7th order for 400 Hz Simultaneous RMS measurements of each phase at 128 samples/cycle and DC Configuration of current and voltage ratios to external PT and CT ratios What's included: USB cable, four black test leads and alligator clips, twelve color-coded ID markers, multifix mounting system, safety card, sensor compliance sheet, 2 GB SD card with USB SD card reader, classic tool bag, power cord, and USB Stick with DataView® software, user manual, quick-start user guide, and three MiniFlex® MA193-10-BK sensors. Specifications Product Type Power Analyzers DC voltage range 50/60 Hz, Single Phase: 100 to 1000 rms 50/60 Hz, Phase to Phase: 100 to 2000 Vrms 400 Hz, Single Phase: 100 to 600 rms 400 Hz, Phase to Phase: 200 to 1200 Vrms DC voltage resolution 50/60 Hz, Single Phase: 0.1 V 50/60 Hz, Phase to Phase: 0.1 to 1 V 400 Hz, Single Phase: 0.1 V 400 Hz, Phase to Phase: 0.1 to 1 V DC voltage accuracy 50/60 Hz, Single Phase: ±0.2% rdg ± 0.2 V 50/60 Hz, Phase to Phase: ±0.2% rdg ± 0.4 V 400 Hz, Single Phase: ±1% rdg ± 1 V 400 Hz, Phase to Phase: ±1% Rdg ± 1 V Dimensions 125 x 256 x 37 mm (W x H x D) Hz 50/60 Hz: 42.5 to 69 400 Hz: 340 to 460 Active power range -2 to 2 GW Active power resolution 0.001 W Active power accuracy ±0.5% rdg ± 0.005% Pnom Reactive power range -2 to 2 Gvar Reactive power resolution 0.001 Var Reactive power accuracy ±1% rdg ± 0.01% Qnom Apparent power range 0 to 2 GVA Apparent power resolution 0.001 VA Apparent power accuracy ±0.5% rdg ± 0.005% Snom Active energy range 0 to 4 x 10 18 Active energy resolution 1 Wh Active energy accuracy ±0.5% rdg Reactive energy range 0 to 4 x 10 18 Reactive energy resolution 1 varh Reactive energy accuracy ±2% rdg Apparent energy range 0 to 4 x 10 18 Apparent energy resolution 1 Vah Apparent energy accuracy ±0.5% rdg Model PEL 102 Qty/ea 1 Manufacturer number PEL 102 Total Harmonic Distortion (THD) ± 655% Brand AEMC Harmonics 1 to 50 displayed in percentage; 1 to 7 at 400 Hz Compliance Complies with IEC 61010-1:Ed3, and IEC 61010-2-030:Ed1 for 1000V CAT III / 600V CAT IV, Pollution Degree 2 Sample rate 128 samples per cycle; 50/60 Hz (16 samples/cycle 400 Hz) Dimensions (" W) 5 Dimensions (" H) 10 Dimensions (" D) 1-1/2 Power 110 to 250 VAC (10%); 50/60 Hz; 400Hz. Rechargeable 8.4 V NiMH battery pack. Make 2137.51
Electrical Test Equipment Power Analyzers AEMC Power and Energy Loggers